Browse all practice questions for the Minnesota Electrical Journeyman Practice Exam. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Minnesota Electrical Journeyman Practice Exam course image
All questions

These questions are part of the practice quiz. Start practicing

  • A.C. and Refrigeration are covered by which article?
  • Why are demand factors used in dwelling load calculations?
  • What is the primary purpose of voltage drop calculations?
  • Which agency administers electrician licensing in Minnesota?
  • NEC 210.8(A) addresses protection by which device?
  • Table 120.42(A) contains demand factors for which loads?
  • Which NEC article governs lighting fixtures and installation requirements?
  • How does the NEC require circuits in a dwelling to be protected against ground faults?
  • Where are the dimensions of pipe found?
  • If P = 1,200 W and I = 6 A, what is V?
  • Which table covers Minimum Wire Bending Space at Terminals and Minimum Width of Wiring Gutters?
  • Voltage drop calculations depend primarily on which electrical quantity?
  • For cables that pass through studs, which distance requires nail plates?
  • Where in the NEC would you find rules about electrical boxes, enclosures, and fittings?
  • Boxes and Raceways are covered by which article?
  • What major safety regulation is commonly associated with electrical work in Minnesota outside of NEC requirements?
  • Article 501 covers which locations?
  • In the Ohm's Law expression E = I × R, what does E represent?
  • Which grounding electrode is embedded in concrete in the building’s foundation?
  • Which NEC article governs conductors, including ampacity and insulation?
  • In voltage drop calculations, which distance is used to represent the length of the conductor run?
  • Which table is used for motor overload rating and protective device rating?
  • For overcurrent protection sizing and devices, which NEC article applies?
  • Which NEC reference addresses Conductor Applications?
  • 210.20 addresses overcurrent protection for which circuits?
  • Which NEC article covers receptacles, outlets, and switches?
  • Which protection is required to detect earth faults and prevent shock hazards in wet locations?
  • Table 120.4 provides references for specific-purpose calculations.
  • Which table provides the minimum depth of clear working space in front of electrical equipment?
  • Which option lists common raceway types used to protect conductors?
  • What is the function of the service disconnect?
  • What does SCCR stand for and why is it important for electrical equipment?
  • Which NEC article governs branch circuits, including receptacles and lighting loads in dwellings?
  • What is the difference between a continuous load and a non-continuous load, and how does that affect OCPD sizing?
  • Which article covers Transformers?
  • Which NEC article covers motors and motor circuits and their protection?
  • Watts Law expresses power as which product?
  • Which article covers Boxes and Raceways?
  • Table 120.55 contains demand factors for which appliances?
  • Article 503 covers which type of locations?
  • Which type of protection is required for many dwelling unit circuits to detect and interrupt arcing faults?
  • What is the purpose of the service disconnecting means?
  • Transformers and disconnecting means are covered by which NEC article?
  • Table 120.55 deals with demand factors for which items?
  • Which table lists cable type markings and permitted uses?
  • Which table contains general lighting load demand factors?
  • In NEC, what governs sizing of conductors for a branch circuit?
  • Which table is used to determine the sizes of wiring gutters and minimum wire bending spaces?
  • Which NEC reference defines Maximum Cord and Plug Rated Connected Load to Receptacles?
  • Which NEC article addresses conductor ampacity and insulation type?
  • Metal Box Sizing is specified in which table?
  • Which NEC reference deals with Grounded Conductor, Main Bonding Jumper, System Bonding Jumper, and Supply Side Bonding Jumper for ac Systems?
  • Which of the following is NOT a raceway type?
  • Where is a service meter typically located?
  • Temporary power installations are addressed by which NEC article?
  • In Watts Law, P = V × I, what does P stand for?
  • Why is a short-circuit current rating (SCCR) important for electrical equipment?
  • Which table covers Motor Overload Rating/Protective Device Rating?
  • If I = 6 A and R = 4 Ω, what is the voltage V?
  • Which table is used for 3-phase motor sizing?
  • PVC Expansion is specified in which table?
  • Which article covers Load Calculations?
  • Which device is designed to detect leakage current to ground and quickly disconnect the circuit to prevent shock?
  • Single Phase Motor Sizing uses which table?
  • Which categories are included in load calculations for dwelling units?
  • Which NEC article provides rules for service equipment and service disconnecting means?
  • Which NEC article governs the location and spacing of lighting outlets and receptacles as part of dwelling branch circuits?
  • When bonding metal parts of a device inside a metal box, which practice ensures a continuous ground path?
  • Why are ampacity adjustment factors applied when multiple current-carrying conductors are in a raceway?
  • Which article provides the method for calculating load for feeders and services?
  • Which of the following is a component commonly used as a grounding electrode?
  • Which article addresses transformers and disconnecting means for transformers?
  • Emergency systems provide what kind of power?
  • Which of the following is NOT a commonly used grounding electrode?
  • Which NEC reference would you use to determine the standard fuse sizes?
  • Wiring Methods are covered by which article?
  • Which document would you consult to verify cable type markings and permitted uses?
  • NM cable securing requirements in residential installations must be secured within 12 inches of boxes and at intervals not exceeding 4.5 feet. Which statement is correct?
  • Which NEC article governs box fills and how is box volume determined?
  • Which NEC table defines Minimum Size Equipment Grounding Conductor for Grounding Raceway and Equipment (EGC)?
  • What is a pigtail and when is it used in branch circuit wiring?
  • Which NEC article covers marinas electrical installations?
  • Which article covers Motors?
  • Which NEC reference addresses Vertical Spacing For Conductor Supports?
  • How many current-carrying conductors in a raceway typically trigger ampacity adjustment factors?
  • Which kitchen electrical requirement drives the use of multiple 20A small-appliance branch circuits?
  • Which term refers to the current-carrying capacity of a conductor?
  • Where are the dimensions of insulated conductors and fixture wires found?
  • Which NEC table defines Vertical Spacing For Conductor Supports?
  • When sizing branch-circuit conductors, what must be considered beyond the conductor's ampacity?
  • What general protection is recommended for outdoor receptacles to ensure safety in wet conditions?
  • Which NEC article covers the service conductors and service disconnecting means?
  • Motors are covered by which article?
  • Which NEC article governs pools, fountains, and spas?
  • The purpose of conductor ampacity in sizing is to determine which of the following?
  • 3 Phase Motor Sizing uses which table?
  • Which table addresses the Minimum Wire Bending Space at Terminals?
  • Overcurrent Protection is covered by which article?
  • What is the purpose of listing and labeling electrical equipment under NEC?
  • Which NEC table covers Grounded Conductor, Main Bonding Jumper, System Bonding Jumper, and Supply Side Bonding Jumper for ac Systems?
  • Which factors require ampacity adjustments or corrections for conductors in NEC calculations?
  • Which NEC article is primarily consulted for grounding and bonding of electrical systems?
  • Which NEC article covers wiring methods, including NM cable, conduit, and flexible cords?
  • Article 502 covers which locations?
  • What does MOP stand for in electrical practice?
  • Which NEC table defines Adjustment Factors For More Than Three Current Carrying Conductors?
  • What is the recommended practice for temporary power distribution to construction sites?
  • Ohm's Law states voltage equals current times resistance. Which equation represents this?
  • Which factor is primarily considered when selecting an enclosure per NEC 110.28?
  • What is the NEC-required minimum working clearance in front of electrical equipment?
  • Electrical installations in health care facilities are covered by which NEC article?
  • Which statement about Minnesota electrical safety rules is true?
  • Voltage Drop K represents what property of the conductor?
  • Table 110.28 is used for which aspect of electrical installations?
  • Which of the following statements about outdoor receptacles is true?
  • Which table lists Wire Ampacities?
  • Which conductor type is commonly used for insulated conductors in raceways?
  • Which NEC reference shows Show Windows?
  • Which statement lists three common conductor types used in modern installations and their general characteristics?
  • In dwelling unit load calculations, which of the following loads is not typically included?
  • NEC 210.12 addresses protection by which device?
  • What is the general purpose of lockout/tagout procedures in electrical work?
  • Motor Overload Rating/Protective Device Rating uses which table?
  • Which NEC reference shows Finding Area Behind a Sink, Range, or Counter Mounted Cooking Unit?
  • Table 110.34(A) provides the minimum depth of clear working space at electrical equipment.
  • Which NEC reference covers Standard Fuse Sizes?
  • Which safety regulation is most commonly associated with electrical work and workplace practices?
  • Why is voltage drop considered in long branch circuits and feeders?
  • Which NEC reference defines Minimum Size Equipment Grounding Conductor for Grounding Raceway and Equipment (EGC)?
  • Which NEC article sets the overall scope and general requirements for all electrical installations?
  • Overcurrent protection (OCP) device sizing determines which of the following?
  • Which NEC article addresses grounding and bonding requirements for electrical systems?
  • In load calculations, what is the purpose of applying demand factors to dwelling units?
  • What is the general purpose of a service meter, and where is it typically located?
  • Which statement best describes the difference between a service disconnect and a branch-circuit disconnect?
  • What does MC cable stand for and what is its general characteristic?
  • NEC 210.20 addresses overcurrent protection for which circuits?
  • Which table lists conductor properties?
  • Which conductor type is nonmetallic sheathed cable commonly used in residential wiring?
  • Which statement best describes the effect of a grounding conductor when bonding a device in a metal box?
  • Which article covers Services?
  • What is essential protection for motor circuits to guard against overloads?
  • PVC Expansion is specified in which table?
  • What does MCA stand for in electrical practice?
  • If V = 240 V and R = 8 Ω, what is I?
  • Conductor Ampacities are addressed in which article?
  • In living areas, what is the maximum distance from any point along a wall to a receptacle?
  • If P = 900 W and V = 180 V, what is I?
  • Which article governs Wiring Methods?
  • Which article covers Conductor Ampacities?
  • What protection must be provided to cables that pass through studs within 1-1/4 inches of the stud edge?
  • Which NEC table defines Minimum Coverage Requirements, 0-1000 Volts?
  • Which NEC article would you consult for wiring methods in a residence, such as NM cable or conduit?
  • What term describes a load that lasts 3 hours or more in electrical calculations?
  • Which statement correctly describes how box fills are determined?
  • In voltage drop calculations, what does KIL stand for?
  • If V = 120 V and I = 2 A, what is P?
  • Transformers are covered by which article?
  • The voltage drop for a single-phase circuit is calculated as which of the following formulas?
  • How should disconnecting means be identified and labeled in a panel?
  • Which NEC table defines Conductor Applications?
  • Grounding and Bonding is addressed by which article?
  • What is the purpose of the equipment grounding conductor?
  • The voltage drop for a three-phase circuit is calculated as which of the following formulas?
  • Which statement best describes the purpose of the short-circuit current rating (SCCR) for electrical equipment?
Subscribe